Determination of boron in silicates after ion exchange separation

Analytical Chemistry
By:

Links

Abstract

Existing methods for the determination of boron in silicates are not entirely satisfactory. Separation as the methyl ester is lengthy and frequently erratic. An accurate and rapid method applicable to glass, mineral, ore, and water samples uses ion exchange to remove interfering cations, and boron is determined titrimetrically in the presence of mannitol, using a pH meter to indicate the end point.
Publication type Article
Publication Subtype Journal Article
Title Determination of boron in silicates after ion exchange separation
Series title Analytical Chemistry
DOI 10.1021/ac60097a049
Volume 27
Issue 1
Year Published 1955
Language English
Publisher ACS Publications
Description 2 p.
First page 144
Last page 145
Google Analytic Metrics Metrics page
Additional publication details