thumbnail

Determination of molybenum in soils and rocks: A geochemical semimicro field method

Analytical Chemistry
By:

Links

  • The Publications Warehouse does not have links to digital versions of this publication at this time
  • Download citation as: RIS | Dublin Core

Abstract

Reconnaissance work in geochemical prospecting requires a simple, rapid, and moderately accurate method for the determination of small amounts of molybdenum in soils and rocks. The useful range of the suggested procedure is from 1 to 32 p.p.m. of molybdenum, but the upper limit can be extended. Duplicate determinations on eight soil samples containing less than 10 p.p.m. of molybdenum agree within 1 p.p.m., and a comparison of field results with those obtained by a conventional laboratory procedure shows that the method is sufficiently accurate for use in geochemical prospecting. The time required for analysis and the quantities of reagents needed have been decreased to provide essentially a "test tube" method for the determination of molybdenum in soils and rocks. With a minimum amount of skill, one analyst can make 30 molybdenum determinations in an 8-hour day.
Publication type Article
Publication Subtype Journal Article
Title Determination of molybenum in soils and rocks: A geochemical semimicro field method
Series title Analytical Chemistry
Volume 23
Issue 5
Year Published 1951
Language English
Larger Work Type Article
Larger Work Subtype Journal Article
Larger Work Title Analytical Chemistry
First page 788
Last page 790
Google Analytic Metrics Metrics page
Additional publication details