Automated solid-phase extraction of herbicides from water for gas chromatographic-mass spectrometric analysis
Links
- More information: Publisher Index Page (via DOI)
- Download citation as: RIS | Dublin Core
Abstract
An automated solid-phase extraction (SPE) method was developed for the pre-concentration of chloroacetanilide and triazine herbicides, and two triazine metabolites from 100-ml water samples. Breakthrough experiments for the C18 SPE cartridge show that the two triazine metabolites are not fully retained and that increasing flow-rate decreases their retention. Standard curve r2 values of 0.998–1.000 for each compound were consistently obtained and a quantitation level of 0.05 μg/l was achieved for each compound tested. More than 10 000 surface and ground water samples have been analyzed by this method.
Publication type | Article |
---|---|
Publication Subtype | Journal Article |
Title | Automated solid-phase extraction of herbicides from water for gas chromatographic-mass spectrometric analysis |
Series title | Journal of Chromatography A |
DOI | 10.1016/0021-9673(93)80353-A |
Volume | 629 |
Issue | 1 |
Year Published | 1993 |
Language | English |
Publisher | Elsevier |
Contributing office(s) | Toxic Substances Hydrology Program |
Description | 5 p. |
First page | 55 |
Last page | 59 |