thumbnail

Relationship between pumping-test and slug-test parameters: Scale effect or artifact?

Ground Water

By:
,

Links

  • The Publications Warehouse does not have links to digital versions of this publication at this time

Abstract

In most field investigations, information about hydraulic conductivity (K) is obtained through pumping or slug tests. A considerable body of data has been amassed that indicates that the K estimate from a pumping test is, on average, considerably larger than the estimate obtained from a series of slug tests in the same formation. Although these data could be interpreted as indicating a natural underlying scale dependence in K, an alternate explanation is that the slug-test K is artificially low as a result of incomplete well development and, to a much lesser extent, failure to account for vertical anisotropy. Incomplete well development will often result in only the most permeable zones being cleared of drilling debris, with much of the screened interval remaining undeveloped. More cursory development can leave a low-K skin along the entire screened interval. Failure to recognize such conditions can result in a K estimate from a slug test that is much lower than the average K of the formation in the vicinity of the well. By contrast, neither a skin nor vertical anisotropy will have a significant impact on K estimates from pumping tests when semi-log analyses and/or observation wells are used. However, a reasonable estimate of aquifer thickness is required to convert the transmissivity calculated from a pumping test Into an average K for the aquifer. Prior to invoking a natural scale dependence to explain the results of different types of hydraulic tests, head data should be closely examined and serious consideration given to alternate explanations.Pumping and slug tests are the primary means to obtain in situ estimates of the transmissive properties of a formation. Since the duration of most pumping tests is on the order of hours to days, the formation volume that is affected by the average pumping test is considerably larger than that affected by a slug test. These tests can yield different parameter estimates when performed at the same well. In this regard, the relationship between pumping test and slug test parameters is examined to provide an explanation to this observed difference. This difference is primarily attributed to incomplete well development and, to a lesser extent, uncertainty concerning aquifer thickness and vertical anisotropy.

Additional Publication Details

Publication type:
Article
Publication Subtype:
Journal Article
Title:
Relationship between pumping-test and slug-test parameters: Scale effect or artifact?
Series title:
Ground Water
Volume
36
Issue:
2
Year Published:
1998
Language:
English
Publisher:
Ground Water Publ Co
Publisher location:
Westerville, OH, United States
Larger Work Type:
Article
Larger Work Subtype:
Journal Article
First page:
305
Last page:
313
Number of Pages:
9