| Abstract: | Semipermeable membrane devices (SPMDs) are used with increasing frequency, and throughout the world as samplers of organic contaminants. The devices can be used to detect a variety of lipophilic chemicals in water, sediment/soil, and air. SPMDs are designed to sample nonpolar, hydrophobic chemicals. The maximum concentration factor achievable for a particular chemical is proportional to its octanol-water partition coefficient. Techniques used for cleanup of SPMD extracts for targeted analytes and for general screening by full-scan mass spectrometry do not differ greatly from techniques used for extracts of other matrices. However, SPMD extracts contain potential interferences that are specific to the membrane-lipid matrix. Procedures have been developed or modified to alleviate these potential interferences. The SPMD approach has been demonstrated to be applicable to sequestering and analyzing a wide array of environmental contaminants including organochlorine pesticides, polychlorinated biphenyls, polycyclic aromatic hydrocarbons, polychlorinated dioxins and dibenzofurans, selected organophosphate pesticides and pyrethroid insecticides, and other nonpolar organic chemicals. We present herein an overview of effective procedural steps for analyzing exposed SPMDs for trace to ultra-trace levels of contaminants sequestered from environmental matrices. Copyright (C) 2000. |
| Genre: | Conference Paper |
| ProdID: | 70022267 |
| Citation Author: | Petty, J. D.; Orazio, C. E.; Huckins, J. N.; Gale, R. W.; Lebo, J. A.; Meadows, J. C.; Echols, K. R.; Cranor, W. L. |
| Citation Contributing Office: | |
| Citation Datum: | |
| Citation Day: | |
| Citation Edition: | |
| Citation Editor: | |
| Citation End Page: | 95 |
| Citation Issue: | 1 |
| Citation Keywords: | |
| Citation Language: | English |
| Citation Larger Work Title: | Journal of Chromatography A |
| Citation LatN: | |
| Citation LatS: | |
| Citation LonE: | |
| Citation LonW: | |
| Citation Month: | |
| Citation No Pagination: | |
| Citation Number Of Pages: | 13 |
| Citation Online Only Flag: | |
| Citation Phsyical Description: | |
| Citation Projection: | |
| Citation Public Comments: | |
| Citation Publisher: | |
| Citation Series: | |
| Citation Series Code: | |
| Citation Series Number: | |
| Citation Search Results Text: | Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants; 2000; Conference Paper; Journal of Chromatography A; Petty, J. D.; Orazio, C. E.; Huckins, J. N.; Gale, R. W.; Lebo, J. A.; Meadows, J. C.; Echols, K. R.; Cranor, W. L. |
| Citation Start Page: | 83 |
| Citation Volume: | 879 |
| Citation Year: | 2000 |
| Type: | citation/reference |
| Text: | Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants; 2000; Conference Paper; Journal of Chromatography A; Petty, J. D.; Orazio, C. E.; Huckins, J. N.; Gale, R. W.; Lebo, J. A.; Meadows, J. C.; Echols, K. R.; Cranor, W. L. |
| URL (THUMBNAIL): | http://pubs.er.usgs.gov/thumbnails/outside_thumb.jpg |
| URL (DIGITAL OBJECT IDENTIFIER): | http://dx.doi.org/10.1016/S0021-9673(00)00315-0 |
| Date Other: | Sat, 1 Jan 2000 00:00 -0600 |
| Publisher: | |