| Abstract: | Global Positioning System (GPS), electronic distance meter, creepmeter, and strainmeter measurements spanning the M 6.0 Parkfield, California, earthquake are examined. Using these data from 100 sec through 9 months following the main-shock, the Omori‘s law, with rate inversely related to time, l/t p and p ranging between 0.7 and 1.3, characterizes the time-dependent deformation during the post-seismic period; these results are consistent with creep models for elastic solids. With an accurate function of postseismic response, the coseismic displacements can be estimated from the high-rate, 1-min sampling GPS; and the coseismic displacements are approximately 75% of those estimated from the daily solutions. Consequently, fault-slip models using daily solutions overestimate coseismic slip. In addition, at 2 months and at 8 months following the mainshock, postseismic displacements are modeled as slip on the San Andreas fault with a lower bound on the moment exceeding that of the coseismic moment. |
| Genre: | Article |
| ProdID: | 70028561 |
| Citation Author: | Langbein, J.; Murray, J. R.; Snyder, H. A. |
| Citation Contributing Office: | |
| Citation Datum: | |
| Citation Day: | |
| Citation Edition: | |
| Citation Editor: | |
| Citation End Page: | |
| Citation Issue: | 4 B |
| Citation Keywords: | |
| Citation Language: | English |
| Citation Larger Work Title: | Bulletin of the Seismological Society of America |
| Citation LatN: | |
| Citation LatS: | |
| Citation LonE: | |
| Citation LonW: | |
| Citation Month: | |
| Citation No Pagination: | |
| Citation Number Of Pages: | |
| Citation Online Only Flag: | |
| Citation Phsyical Description: | |
| Citation Projection: | |
| Citation Public Comments: | |
| Citation Publisher: | |
| Citation Series: | |
| Citation Series Code: | |
| Citation Series Number: | |
| Citation Search Results Text: | Coseismic and initial postseismic deformation from the 2004 Parkfield, California, earthquake, observed by global positioning system, electronic distance meter, creepmeters, and borehole strainmeters; 2006; Article; Journal; Bulletin of the Seismological Society of America; Langbein, J.; Murray, J. R.; Snyder, H. A. |
| Citation Start Page: | |
| Citation Volume: | 96 |
| Citation Year: | 2006 |
| Type: | citation/reference |
| Text: | Coseismic and initial postseismic deformation from the 2004 Parkfield, California, earthquake, observed by global positioning system, electronic distance meter, creepmeters, and borehole strainmeters; 2006; Article; Journal; Bulletin of the Seismological Society of America; Langbein, J.; Murray, J. R.; Snyder, H. A. |
| URL (THUMBNAIL): | http://pubs.er.usgs.gov/thumbnails/outside_thumb.jpg |
| URL (DIGITAL OBJECT IDENTIFIER): | http://dx.doi.org/10.1785/0120050823 |
| Date Other: | Sun, 1 Jan 2006 00:00 -0600 |
| Publisher: | |