| Abstract: | A battery powered submersible chemical analyzer, the Zn-DigiScan (Zn Digital Submersible Chemical Analyzer), has been developed for near real-time, in situ monitoring of zinc in aquatic systems. Microprocessor controlled solenoid pumps propel sample and carrier through an anion exchange column to separate zinc from interferences, add colorimetric reagents, and propel the reaction complex through a simple photometric detector. The Zn-DigiScan is capable of self-calibration with periodic injections of standards and blanks. The detection limit with this approach was 30 ??g L-1. Precision was 5-10% relative standard deviation (R.S.D.) below 100 ??g L-1, improving to 1% R.S.D. at 1000 ??g L-1. The linear range extended from 30 to 3000 ??g L-1. In situ field results were in agreement with samples analyzed by inductively coupled plasma mass spectrometry (ICPMS). This pump technology is quite versatile and colorimetric methods with complex online manipulations such as column reduction, preconcentration, and dilution can be performed with the DigiScan. However, long-term field deployments in shallow high altitude streams were hampered by air bubble formation in the photometric detector. ?? 2005 Elsevier B.V. All rights reserved. |
| Genre: | Article |
| ProdID: | 70029638 |
| Citation Author: | Chapin, T. P.; Wanty, R. B. |
| Citation Contributing Office: | |
| Citation Datum: | |
| Citation Day: | |
| Citation Edition: | |
| Citation Editor: | |
| Citation End Page: | 208 |
| Citation Issue: | 1-2 |
| Citation Keywords: | |
| Citation Language: | English |
| Citation Larger Work Title: | Analytica Chimica Acta |
| Citation LatN: | |
| Citation LatS: | |
| Citation LonE: | |
| Citation LonW: | |
| Citation Month: | |
| Citation No Pagination: | |
| Citation Number Of Pages: | 10 |
| Citation Online Only Flag: | |
| Citation Phsyical Description: | |
| Citation Projection: | |
| Citation Public Comments: | |
| Citation Publisher: | |
| Citation Series: | |
| Citation Series Code: | |
| Citation Series Number: | |
| Citation Search Results Text: | Development of a solenoid pumped in situ zinc analyzer for environmental monitoring; 2005; Article; Journal; Analytica Chimica Acta; Chapin, T. P.; Wanty, R. B. |
| Citation Start Page: | 199 |
| Citation Volume: | 543 |
| Citation Year: | 2005 |
| Type: | citation/reference |
| Text: | Development of a solenoid pumped in situ zinc analyzer for environmental monitoring; 2005; Article; Journal; Analytica Chimica Acta; Chapin, T. P.; Wanty, R. B. |
| URL (THUMBNAIL): | http://pubs.er.usgs.gov/thumbnails/outside_thumb.jpg |
| URL (DIGITAL OBJECT IDENTIFIER): | http://dx.doi.org/10.1016/j.aca.2005.04.046 |
| Date Other: | Sat, 1 Jan 2005 00:00 -0600 |
| Publisher: | |