| Abstract: | In wild birds implanted intracoelomically with radio transmitters, a synthetic fabric collar placed around the base of a percutaneous antenna is believed to function as a barrier to contamination of the coelom. We examined 13 fabric collars recovered from percutaneous antennas of radio transmitters implanted intracoelomically in harlequin ducks (Histrionicus histrionicus) 12 months earlier. Both the transmitters and antenna collars were encapsulated in fibrous connective tissue, with adhesions to internal organs. Histologically, bacteria were evident at the fabric-plastic interface in 8 of 10 collars examined in cross section and along the length of the collar in 3 collars examined longitudinally. Bacteria were confined within the fibrotic sheath surrounding the transmitter and the antenna collar in all birds. No evidence of chronic systemic effects secondary to implantation was present on hematologic or serum biochemical testing. These findings indicate that antenna collars do not prevent the entry of bacteria along the percutaneous antenna but may help stabilize the antenna and minimize coelomic contamination. We conclude that radio transmitters implanted into the coelom of harlequin ducks do not appear to cause significant health problems for at least 1 year after implantation. ?? 2007 by the Association of Avian Veterinarians. |
| Genre: | Article |
| ProdID: | 70032118 |
| Citation Author: | Mulcahy, D. M.; Burek, K. A.; Esler, D. |
| Citation Contributing Office: | |
| Citation Datum: | |
| Citation Day: | |
| Citation Edition: | |
| Citation Editor: | |
| Citation End Page: | 21 |
| Citation Issue: | 1 |
| Citation Keywords: | |
| Citation Language: | English |
| Citation Larger Work Title: | Journal of Avian Medicine and Surgery |
| Citation LatN: | |
| Citation LatS: | |
| Citation LonE: | |
| Citation LonW: | |
| Citation Month: | |
| Citation No Pagination: | |
| Citation Number Of Pages: | 9 |
| Citation Online Only Flag: | |
| Citation Phsyical Description: | |
| Citation Projection: | |
| Citation Public Comments: | |
| Citation Publisher: | |
| Citation Series: | |
| Citation Series Code: | |
| Citation Series Number: | |
| Citation Search Results Text: | Inflammatory reaction to fabric collars from percutaneous antennas attached to intracoelomic radio transmitters implanted in harlequin ducks (Histrionicus histrionicus); 2007; Article; Journal; Journal of Avian Medicine and Surgery; Mulcahy, D. M.; Burek, K. A.; Esler, D. |
| Citation Start Page: | 13 |
| Citation Volume: | 21 |
| Citation Year: | 2007 |
| Type: | citation/reference |
| Text: | Inflammatory reaction to fabric collars from percutaneous antennas attached to intracoelomic radio transmitters implanted in harlequin ducks (Histrionicus histrionicus); 2007; Article; Journal; Journal of Avian Medicine and Surgery; Mulcahy, D. M.; Burek, K. A.; Esler, D. |
| URL (THUMBNAIL): | http://pubs.er.usgs.gov/thumbnails/outside_thumb.jpg |
| URL (DIGITAL OBJECT IDENTIFIER): | http://dx.doi.org/10.1647/1082-6742(2007)21[13:IRTFCF]2.0.CO;2 |
| Date Other: | Mon, 1 Jan 2007 00:00 -0600 |
| Publisher: | |