| Abstract: | Satellite data from the Surrey Satellite Technology Limited (SSTL) United Kingdom (UK) Disaster Monitoring Constellation (DMC) were assessed for geometric and radiometric quality. The UK-DMC Surrey Linear Imager 6 (SLIM-6) sensor has a 32-m spatial resolution and a ground swath width of 640 km. The UK-DMC SLIM-6 design consists of a three-band imager with green, red, and near-infrared bands that are set to similar bandpass as Landsat bands 2, 3, and 4. The UK-DMC data consisted of imagery registered to Landsat orthorectified imagery produced from the GeoCover program. Relief displacements within the UK-DMC SLIM-6 imagery were accounted for by using global 1-km digital elevation models available through the Global Land One-km Base Elevation (GLOBE) Project. Positional accuracy and relative band-to-band accuracy were measured. Positional accuracy of the UK-DMC SLIM-6 imagery was assessed by measuring the imagery against digital orthophoto quadrangles (DOQs), which are designed to meet national map accuracy standards at 1:24000 scales; this corresponds to a horizontal root-mean-square accuracy of about 6 m. The UK-DMC SLIM-6 images were typically registered to within 1.01.5 pixels to the DOQ mosaic images. Several radiometric artifacts like striping, coherent noise, and flat detector were discovered and studied. Indications are that the SSTL UK-DMC SLIM-6 data have few artifacts and calibration challenges, and these can be adjusted or corrected via calibration and processing algorithms. The cross-calibration of the UK-DMC SLIM-6 and Landsat 7 Enhanced Thematic Mapper Plus was performed using image statistics derived from large common areas observed by the two sensors. ?? 2006 IEEE. |
| Genre: | Article |
| ProdID: | 70036281 |
| Citation Author: | Chander, G.; Saunier, S.; Choate, M. J.; Scaramuzza, P. L. |
| Citation Contributing Office: | |
| Citation Datum: | |
| Citation Day: | |
| Citation Edition: | |
| Citation Editor: | |
| Citation End Page: | 2391 |
| Citation Issue: | 7 |
| Citation Keywords: | |
| Citation Language: | English |
| Citation Larger Work Title: | IEEE Transactions on Geoscience and Remote Sensing |
| Citation LatN: | |
| Citation LatS: | |
| Citation LonE: | |
| Citation LonW: | |
| Citation Month: | |
| Citation No Pagination: | |
| Citation Number Of Pages: | 12 |
| Citation Online Only Flag: | |
| Citation Phsyical Description: | |
| Citation Projection: | |
| Citation Public Comments: | |
| Citation Publisher: | |
| Citation Series: | |
| Citation Series Code: | |
| Citation Series Number: | |
| Citation Search Results Text: | SSTL UK-DMC SLIM-6 data quality assessment; 2009; Article; Journal; IEEE Transactions on Geoscience and Remote Sensing; Chander, G.; Saunier, S.; Choate, M. J.; Scaramuzza, P. L. |
| Citation Start Page: | 2380 |
| Citation Volume: | 47 |
| Citation Year: | 2009 |
| Type: | citation/reference |
| Text: | SSTL UK-DMC SLIM-6 data quality assessment; 2009; Article; Journal; IEEE Transactions on Geoscience and Remote Sensing; Chander, G.; Saunier, S.; Choate, M. J.; Scaramuzza, P. L. |
| URL (THUMBNAIL): | http://pubs.er.usgs.gov/thumbnails/outside_thumb.jpg |
| URL (DIGITAL OBJECT IDENTIFIER): | http://dx.doi.org/10.1109/TGRS.2009.2013206 |
| Date Other: | Thu, 1 Jan 2009 00:00 -0600 |
| Publisher: | |