On the use of high-resolution topographic data as a proxy for seismic site conditions (VS30)

Bulletin of the Seismological Society of America
By:  and 

Links

Abstract

An alternative method has recently been proposed for evaluating global seismic site conditions, or the average shear velocity to 30 m depth (VS30), from the Shuttle Radar Topography Mission (SRTM) 30 arcsec digital elevation models (DEMs). The basic premise of the method is that the topographic slope can be used as a reliable proxy for VS30 in the absence of geologically and geotechnically based site-condition maps through correlations between VS30 measurements and topographic gradient. Here we evaluate the use of higher-resolution (3 and 9 arcsec) DEMs to examine whether we are able to resolve VS30 in more detail than can be achieved using the lower-resolution SRTM data. High-quality DEMs at resolutions greater than 30 arcsec are not uniformly available at the global scale. However, in many regions where such data exist, they may be employed to resolve finer-scale variations in topographic gradient, and consequently, VS30. We use the U.S. Geological Survey Earth Resources Observation and Science (EROS) Data Center's National Elevation Dataset (NED) to investigate the use of high-resolution DEMs for estimating VS30 in several regions across the United States, including the San Francisco Bay area in California, Los Angeles, California, and St. Louis, Missouri. We compare these results with an example from Taipei, Taiwan, that uses 9 arcsec SRTM data, which are globally available. The use of higher-resolution NED data recovers finer-scale variations in topographic gradient, which better correlate to geological and geomorphic features, in particular, at the transition between hills and basins, warranting their use over 30 arcsec SRTM data where available. However, statistical analyses indicate little to no improvement over lower-resolution topography when compared to VS30 measurements, suggesting that some topographic smoothing may provide more stable VS30 estimates. Furthermore, we find that elevation variability in canopy-based SRTM measurements at resolutions greater than 30 arcsec are too large to resolve reliable slopes, particularly in low-gradient sedimentary basins.
Publication type Article
Publication Subtype Journal Article
Title On the use of high-resolution topographic data as a proxy for seismic site conditions (VS30)
Series title Bulletin of the Seismological Society of America
DOI 10.1785/0120080255
Volume 99
Issue 2 A
Year Published 2009
Language English
Larger Work Type Article
Larger Work Subtype Journal Article
Larger Work Title Bulletin of the Seismological Society of America
First page 935
Last page 943
Google Analytic Metrics Metrics page
Additional publication details