The influence of sample matrix on the accuracy of nitrite N and O isotope ratio analyses with the azide method

Rapid Communications in Mass Spectrometry
By: , and 

Links

Abstract

Rationale

The isotope ratios of nitrogen (15N/14N) and oxygen (18O/16O) in nitrite (NO2) can be measured by conversion of the nitrite into nitrous oxide (N2O) with azide, followed by mass spectrometric analysis of N2O by gas chromatography isotope ratio mass spectrometry (GC/IRMS). While applying this method to brackish samples, we noticed that the N and O isotope ratio measurements of NO2 are highly sensitive to sample salinity and to the pH at which samples are preserved.

Methods

We investigated the influence of sample salinity and sample preservation pH on the N and O isotope ratios of the N2O produced from the reaction of NO2 with azide. The N2O isotope ratios were measured by GC/IRMS.

Results

Under the experimental reaction conditions, the conversion of NO2 into N2O was less complete in lower salinity solutions, resulting in respective N and O isotopic offsets of +2.5‰ and −14.0‰ compared with seawater solutions. Differences in salinity were also associated with differences in the fraction of O atoms exchanged between NO2 and water during the reaction. Similarly, aqueous NO2 samples preserved at elevated pH values resulted in the incomplete conversion of NO2 into N2O by azide, and consequent pH‐dependent isotopic offsets, as well as differences in the fraction of O atoms exchanged with water. The addition of sodium chloride to the reaction matrix of samples and standards largely mitigated salinity‐dependent isotopic offsets in the N2O product, and nearly homogenized the fraction of O atom exchange among samples of different salinity. A test of the hypobromite–azide method to measure N isotope ratios of ammonium by conversion into NO2 then N2O revealed no influence of sample salinity on the N isotope ratios of the N2O product.

Conclusions

We outline recommendations to mitigate potential matrix effects among samples and standards, to improve the accuracy of N and O isotope ratios in NO2 measured with the azide method.

Publication type Article
Publication Subtype Journal Article
Title The influence of sample matrix on the accuracy of nitrite N and O isotope ratio analyses with the azide method
Series title Rapid Communications in Mass Spectrometry
DOI 10.1002/rcm.8569
Volume 34
Year Published 2020
Language English
Publisher Wiley
Contributing office(s) WMA - Earth System Processes Division
Description e8569, 12 p.
Google Analytic Metrics Metrics page
Additional publication details