Selected hydrologic data for the field demonstration of three permeable reactive barriers near Fry Canyon, Utah, 1996-2000

Open-File Report 2001-361
By: , and 

Links

Abstract

Three permeable reactive barriers (PRBs) were installed near Fry Canyon, Utah, in August 1997 to demonstrate the use of PRBs to control the migration of uranium in ground water. Reactive material included (1) bone-char phosphate, (2) zero-valent iron pellets, and (3) amorphous ferric oxyhydroxide coated gravel. An extensive monitoring network was installed in and around each PRB for collection of water samples, analysis of selected water-quality parameters, and monitoring of water levels. Water temperature, specific conductance, pH, Eh (oxidation-reduction potential), and dissolved oxygen were measured continuously within three different barrier materials, and in two monitoring wells. Water temperature and water level below land surface were electronically recorded every hour with pressure transducers. Data were collected from ground-water monitoring wells installed in and around the PRBs during 1996-98 and from surface-water sites in Fry Creek.

Study Area

Publication type Report
Publication Subtype USGS Numbered Series
Title Selected hydrologic data for the field demonstration of three permeable reactive barriers near Fry Canyon, Utah, 1996-2000
Series title Open-File Report
Series number 2001-361
DOI 10.3133/ofr01361
Year Published 2001
Language English
Publisher U.S. Geological Survey
Publisher location Salt Lake City, UT
Contributing office(s) Utah Water Science Center
Description vii, 102 p.
Country United States
State Utah
Other Geospatial Fry Canyon
Google Analytic Metrics Metrics page
Additional publication details