Analog-model studies of ground-water hydrology in the Houston District, Texas
Links
- Document: Report (26972 pdf)
- Plates:
- Plate 1 (9012 pdf)
- Plate 2 (4740 pdf)
- Plate 3 (3451 pdf)
- Plate 4 (2351 pdf)
- Plate 5 (2992 pdf)
- Plate 6 (3022 pdf)
- Plate 7 (2938 pdf)
- Plate 8 (3099 pdf)
- Plate 9 (3491 pdf)
- Plate 10 (3185 pdf)
- Plate 11 (3569 pdf)
- Plate 12 (3311 pdf)
- Plate 13 (3232 pdf)
- Plate 14 (3448 pdf)
- Plate 15 (3904 pdf)
- Plate 16 (2076 pdf)
- Plate 17 (3356 pdf)
- Plate 18 (2911 pdf)
- Plate 19 (3452 pdf)
- Plate 20 (3790 pdf)
- Plate 21 (2695 pdf)
- Plate 22 (1868 pdf)
- Plate 23 (1740 pdf)
- Plate 24 (2007 pdf)
- Plate 25 (1731 pdf)
- Plate 26 (3503 pdf)
- Plate 27 (2932 pdf)
- Plate 28 (3048 pdf)
- Plate 29 (3884 pdf)
- Plate 30 (3176 pdf)
- Plate 31 (3093 pdf)
- Plate 32 (3280 pdf)
- Plate 33 (1261 pdf)
- Download citation as: RIS | Dublin Core
Abstract
The major water-bearing units in the Houston district are the Chicot and the Evangeline aquifers. The Chicot aquifer overlies the Evangeline aquifer, which is underlain by the Burkeville confining layer. Both aquifers consist of unconsolidated and discontinuous layers of sand and clay that dip toward the Gulf of Mexico. Heavy pumping of fresh water has caused large declines in the altitudes of the potentiometric surfaces in both aquifers and has created large cones of depression around Houston. The declines have caused compaction of clay layers, which has resulted in land surface subsidence and the movement of saline ground water toward the centers of the cones of depression. An electric analog model was used to study the hydrologic system and to simulate the declines in the altitudes of the potentiometric surfaces for several alternative plans of ground-water development. The results indicate that the largest part. of the pumped water comes from storage in the water-table part of the Chicot aquifer. Vertical leakage from the aquifers and water derived from the compaction of clay layers in the aquifers are also large sources of the water being pumped. The response of the system, as observed on the model, indicates that development of additional ground-water supplies from the water-table part of the Chicot aquifer north of Houston would result in a minimum decline of the altitudes of the potentiometric surfaces. Total withdrawals of about 1,000 million gallons (5.8 million cubic meters) per day may be possible without seriously, increasing subsidence or salt-water encroachment. Analyses of the recovery of water levels indicate that both land-surface subsidence and salt-water encroachment could be reduced by artificially recharging the artesian part of the aquifer.
Publication type | Report |
---|---|
Publication Subtype | USGS Numbered Series |
Title | Analog-model studies of ground-water hydrology in the Houston District, Texas |
Series title | Open-File Report |
Series number | 74-113 |
DOI | 10.3133/ofr74113 |
Year Published | 1974 |
Language | English |
Publisher | U.S. Geological Survey |
Contributing office(s) | Texas Water Science Center |
Description | Report: x, 86 p.; 33 Plates |
Online Only (Y/N) | N |
Additional Online Files (Y/N) | N |
Google Analytic Metrics | Metrics page |