| Abstract: | Water samples for trace-metal determinations routinely have been prepared in open laboratories. For example, the U.S. Geological Survey method I-3485-85 (Extraction Procedure, for Water- Suspended Sediment) is performed in a laboratory hood on a laboratory bench without any special precautions to control airborne contamination. This method tends to be contamination prone for several trace metals primarily because the samples are transferred, acidified, digested, and filtered in an open laboratory environment. To reduce trace-metal contamination of digested water samples, procedures were established that rely on minimizing sample-transfer steps and using a class-100 clean bench during sample filtration. This new procedure involves the following steps: 1. The sample is acidified with HCl directly in the original water-sample bottle. 2. The water-sample bottle with the cap secured is heated in a laboratory oven. 3. The digestate is filtered in a class-100 laminar-flow clean bench. The exact conditions used (that is, oven temperature, time of heating, and filtration methods) for this digestion procedure are described. Comparisons between the previous U.S Geological Survey open-beaker method I-3485-85 and the new in-bottle procedure for synthetic and field-collected water samples are given. When the new procedure is used, blank concentrations for most trace metals determined are reduced significantly. |
| Genre: | USGS Numbered Series |
| ProdID: | 23362 |
| Citation Author: | Hoffman, G. L.; Fishman, M. J.; Garbarino, J. R. |
| Citation Contributing Office: | |
| Citation Datum: | |
| Citation Day: | |
| Citation Edition: | - |
| Citation Editor: | |
| Citation End Page: | |
| Citation Issue: | |
| Citation Keywords: | |
| Citation Language: | ENGLISH |
| Citation Larger Work Title: | |
| Citation LatN: | |
| Citation LatS: | |
| Citation LonE: | |
| Citation LonW: | |
| Citation Month: | |
| Citation No Pagination: | |
| Citation Number Of Pages: | |
| Citation Online Only Flag: | |
| Citation Phsyical Description: | vi, 28 p. :ill. ;28 cm. |
| Citation Projection: | |
| Citation Public Comments: | |
| Citation Publisher: | U.S. Geological Survey :
U.S. Geological Survey Branch of Information Services [distributor], |
| Citation Series: | Open-File Report |
| Citation Series Code: | OFR |
| Citation Series Number: | 96-225 |
| Citation Search Results Text: | Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; in-bottle acid digestion of whole-water samples; 1996; OFR; 96-225; Hoffman, G. L.; Fishman, M. J.; Garbarino, J. R. |
| Citation Start Page: | |
| Citation Volume: | |
| Citation Year: | 1996 |
| Type: | citation/reference |
| Text: | Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; in-bottle acid digestion of whole-water samples; 1996; OFR; 96-225; Hoffman, G. L.; Fishman, M. J.; Garbarino, J. R. |
| URL (THUMBNAIL): | http://pubs.usgs.gov/of/1996/0225/report-thumb.jpg |
| URL (DOCUMENT): | http://pubs.usgs.gov/of/1996/0225/report.pdf |
| Date Other: | Fri, 10 Jan 1997 00:00 -0600 |
| Publisher: | U.S. Geological Survey :
U.S. Geological Survey Branch of Information Services [distributor], |