| Abstract: | A pressurized stormwater filtration system was installed in 1998 as a stormwater-treatment practice to treat runoff from a hospital rooftop and parking lot in Green Bay, Wisconsin. This type of filtration system has been installed in Florida citrus groves and sewage treatment plants around the United States; however, this installation is the first of its kind to be used to treat urban runoff and the first to be tested in Wisconsin. The U.S. Geological Survey (USGS) monitored the system between November 2000 and September 2002 to evaluate it as part of the U.S. Environmental Protection Agency‘s Environmental Technology Verification Program. Fifteen runoff events were monitored for flow and water quality at the inlet and outlet of the system, and comparison of the event mean concentrations and constituent loads was used to evaluate its effectiveness. Loads were decreased in all particulate-associated constituents monitored, including suspended solids (83 percent), suspended sediment (81 percent), total Kjeldahl nitrogen (26 percent), total phosphorus (54 percent), and total recoverable zinc (62 percent). Total dissolved solids, dissolved phosphorus, and nitrate plus nitrite loads remained similar or increased through the system. The increase in some constituents was most likely due to a ground-water contribution between runoff events. Sand/silt split analysis resulted in the median silt content of 78 percent at the inlet, 87 percent at the outlet, and 3 percent at the flow splitter. |
| Genre: | USGS Numbered Series |
| ProdID: | 70193 |
| Citation Author: | Horwatich, J. A.; Corsi, Steven R.; Bannerman, Roger T. |
| Citation Contributing Office: | |
| Citation Datum: | |
| Citation Day: | |
| Citation Edition: | - |
| Citation Editor: | |
| Citation End Page: | |
| Citation Issue: | |
| Citation Keywords: | |
| Citation Language: | ENGLISH |
| Citation Larger Work Title: | |
| Citation LatN: | |
| Citation LatS: | |
| Citation LonE: | |
| Citation LonW: | |
| Citation Month: | |
| Citation No Pagination: | |
| Citation Number Of Pages: | 27 |
| Citation Online Only Flag: | |
| Citation Phsyical Description: | 27 p. |
| Citation Projection: | |
| Citation Public Comments: | |
| Citation Publisher: | |
| Citation Series: | Scientific Investigations Report |
| Citation Series Code: | SIR |
| Citation Series Number: | 2004-5222 |
| Citation Search Results Text: | Effectiveness of a pressurized stormwater filtration system in Green Bay, Wisconsin: a study for the environmental technology verification program of the U.S. Environmental Protection Agency; 2004; SIR; 2004-5222; Horwatich, J. A.; Corsi, Steven R.; Bannerman, Roger T. |
| Citation Start Page: | |
| Citation Volume: | |
| Citation Year: | 2004 |
| Type: | citation/reference |
| Text: | Effectiveness of a pressurized stormwater filtration system in Green Bay, Wisconsin: a study for the environmental technology verification program of the U.S. Environmental Protection Agency; 2004; SIR; 2004-5222; Horwatich, J. A.; Corsi, Steven R.; Bannerman, Roger T. |
| URL (THUMBNAIL): | http://pubs.er.usgs.gov/thumbnails/usgs_thumb.jpg |
| URL (INDEX PAGE): | http://pubs.water.usgs.gov/sir2004-5222/ |
| Date Other: | Fri, 11 Mar 2005 00:00 -0600 |
| Publisher: | |