| Abstract: | The U.S. Geological Survey, in cooperation with the Naval Facilities Engineering Command Southeast, used newly developed sampling methods to investigate ground-water contamination by chlorobenzenes beneath a drainage ditch on the southwestern side of Installation Restoration Site 4, Naval Air Station Corpus Christi, Corpus Christi, Texas, during 2005-06. The drainage ditch, which is a potential receptor for ground-water contaminants from Installation Restoration Site 4, intermittently discharges water to Corpus Christi Bay. This report uses data from a new type of pore-water sampler developed for this investigation and other methods to examine the subsurface contamination beneath the drainage ditch. Analysis of ground water from the samplers indicated that chlorobenzenes (maximum detected concentration of 160 micrograms per liter) are present in the ground water beneath the ditch. The concentrations of dissolved oxygen in the samples (less than 0.05-0.4 milligram per liter) showed that the ground water beneath and near the ditch is anaerobic, indicating that substantial chlorobenzene biodegradation in the aquifer beneath the ditch is unlikely. Probable alternative mechanisms of chlorobenzene removal in the ground water beneath the drainage ditch include sorption onto the organic-rich sediment and contaminant depletion by cattails through uptake, sorption, and localized soil aeration. |
| Genre: | USGS Numbered Series |
| ProdID: | 80522 |
| Citation Author: | Vroblesky, Don A.; Casey, Clifton C. |
| Citation Contributing Office: | South Carolina Water Science Center |
| Citation Datum: | |
| Citation Day: | |
| Citation Edition: | |
| Citation Editor: | |
| Citation End Page: | |
| Citation Issue: | |
| Citation Keywords: | |
| Citation Language: | English |
| Citation Larger Work Title: | |
| Citation LatN: | |
| Citation LatS: | |
| Citation LonE: | |
| Citation LonW: | |
| Citation Month: | Oct |
| Citation No Pagination: | |
| Citation Number Of Pages: | |
| Citation Online Only Flag: | Y |
| Citation Phsyical Description: | iv, 7 p. |
| Citation Projection: | |
| Citation Public Comments: | Prepared in cooperation with the Naval Facilities Engineering Command Southeast |
| Citation Publisher: | U.S. Geological Survey |
| Citation Series: | Scientific Investigations Report |
| Citation Series Code: | SIR |
| Citation Series Number: | 2007-5155 |
| Citation Search Results Text: | Investigation of ground-water contamination at a drainage ditch, Installation Restoration Site 4, Naval Air Station Corpus Christi, Corpus Christi, Texas, 2005–06; 2007; SIR; 2007-5155; Vroblesky, Don A.; Casey, Clifton C. |
| Citation Start Page: | |
| Citation Volume: | |
| Citation Year: | 2007 |
| Type: | citation/reference |
| Text: | Investigation of ground-water contamination at a drainage ditch, Installation Restoration Site 4, Naval Air Station Corpus Christi, Corpus Christi, Texas, 2005–06; 2007; SIR; 2007-5155; Vroblesky, Don A.; Casey, Clifton C. |
| URL (THUMBNAIL): | http://pubs.er.usgs.gov/thumbnails/usgs_thumb.jpg |
| URL (INDEX PAGE): | http://pubs.usgs.gov/sir/2007/5155/ |
| Date Other: | Wed, 10 Oct 2007 00:00 -0500 |
| Publisher: | U.S. Geological Survey |