Design, operation, and monitoring capability of an experimental artificial-recharge facility at East Meadow, Long Island, New York

Water-Resources Investigations Report 84-4321
By:  and 

Links

Abstract

Artificial recharge with tertiary-treated sewage is being tested at East Meadow to evaluate the physical and chemical effects on the groundwater system. The recharge facility contains 11 recharge basins and 5 injection wells and is designed to accept 4 million gallons of reclaimed water per day. Of the 11 basins, 7 are recently constructed and will accept 0.5 million gallons per day each. An observation manhole (12-foot inside diameter and extending 16 feet below the basin floor) was installed in each of two basins to enable monitoring and sampling of percolating reclaimed water in the unsaturated zone with instruments such as tensiometers, gravity lysimeters, thermocouples, and soil-gas samplers. Five shallow (100-feet deep) injection wells will each return 0.5 million gallons per day to the groundwater reservoir. Three types of injection-well design are being tested; the differences are in the type of gravel pack around the well screen. When clogging at the well screen occurs, redevelopment should restore the injection capability. Flow to the basins and wells is regulated by automatic flow controllers in which a desired flow rate is maintained by electronic sensors. Basins can also operate in a constant-head mode in which a specified head is maintained in the basin automatically. An observation-well network consisting of 2-inch- and 6-inch-diameter wells was installed within a 1-square-mile area at the recharge facility to monitor aquifer response and recharge. During 48 days of operation within a 17-week period (October 1982 through January 1983), 88.5 million gallons of reclaimed water was applied to the shallow water table aquifer through the recharge basins. A 4.29-foot-high groundwater mound developed during a 14-day test; some water level increase associated with the mound was detected 1,000 ft from the basins. Preliminary water quality data from wells affected by reclaimed water show evidence that mechanisms of mixing, dilution, and dispersion are affecting chemical concentrations of certain constituents, such as nitrogen and trichloroethane, in the shallow aquifer beneath the recharge area. (USGS)
Publication type Report
Publication Subtype USGS Numbered Series
Title Design, operation, and monitoring capability of an experimental artificial-recharge facility at East Meadow, Long Island, New York
Series title Water-Resources Investigations Report
Series number 84-4321
DOI 10.3133/wri844321
Edition -
Year Published 1986
Language ENGLISH
Publisher U.S. Geological Survey,
Description vi, 46 p. :ill., maps ;28 cm.
Google Analytic Metrics Metrics page
Additional publication details