thumbnail

Radon in earth-sheltered structures

Underground Space
By:

Links

  • The Publications Warehouse does not have links to digital versions of this publication at this time
  • Download citation as: RIS | Dublin Core

Abstract

Radon concentration in the indoor air of six residential and three non-residential earth-sheltered buildings in eastern Colorado was monitored quarterly over a nine-month period using passive, integrating detectors. Average radon concentrations during the three-month sampling periods ranged from about 1 to 9 pCi/L, although one building, a poorly ventilated storage bunker, had concentrations as high as 39 pCi/L. These radon concentrations are somewhat greater than those typically reported for conventional buildings (around 1 pCi/L); but they are of the same order of magnitude as radon concentrations reported for energy-efficient buildings which are not earth-sheltered. ?? 1984.

Additional publication details

Publication type Article
Publication Subtype Journal Article
Title Radon in earth-sheltered structures
Series title Underground Space
Volume 8
Issue 4
Year Published 1984
Language English
Larger Work Type Article
Larger Work Subtype Journal Article
Larger Work Title Underground Space
First page 264
Last page 269
Google Analytic Metrics Metrics page