Abstract

The Delft Bottle (DB) is a flow-through device designed by the Delft Hydraulic Laboratory (DHL), The Netherlands, to sample sand-sized sediment suspended in streams. The US P-61 sampler was designed by the Federal Interagency Sedimentation Project (FISP) at the St. Anthony Falls Hydraulic Laboratory, Minneapolis, Minnesota, to collect suspended sediment from deep, swift rivers. The results of two point-sampling tests in the United States, the Mississippi River near Vicksburg, Mississippi, in 1983 and the Colorado River near Blythe, California, in 1984, are provided in this report. These studies compare sand-transport rates, rather than total sediment-transport rates, because fine material washes through the DB sampler. In the United States, the commonly used limits for sand-sized material are 0.062 mm to 2.00 mm (Vanoni 1975).
Publication type Article
Publication Subtype Journal Article
Title Comparison. US P-61 and Delft sediment samplers
Series title Journal of Hydraulic Engineering
Volume 115
Issue 12
Year Published 1990
Language English
Larger Work Type Article
Larger Work Subtype Journal Article
Larger Work Title Journal of Hydraulic Engineering
First page 1702
Last page 1706
Google Analytic Metrics Metrics page
Additional publication details