Survey‐net adjustment by electrical analogue

Eos, Transactions, American Geophysical Union
By:

Links

Abstract

This paper describes how the equivalent of a least‐squares adjustment of a level or traverse net may be obtained by electrical measurements in an analogous electrical net. The lengths of the survey lines are replaced by proportional electrical resistances; the survey closures are replaced by proportional small dc voltages; the adjustment corrections are read as electrical potentials at the various junction points. The resistances, power units, and junction jacks are mounted on a panel, and are interconnected by jumpers. The closure and correction voltages are read with a special type feed‐back voltmeter.

Publication type Article
Publication Subtype Journal Article
Title Survey‐net adjustment by electrical analogue
Series title Eos, Transactions, American Geophysical Union
DOI 10.1029/TR028i006p00831
Volume 28
Issue 6
Year Published 1947
Language English
Publisher American Geophysical Union
Description 7 p.
First page 831
Last page 837
Google Analytic Metrics Metrics page
Additional publication details