Determination of pentachlorophenol in water and aquifer sediments by high-performance liquid chromatography

Open-File Report 82-124
By:

Links

Abstract

Methods for the determination of pentachlorophenol (PCP) in water and aquifer sediments are presented. Reverse-phase high-performance liquid chromotography employing ion suppression and gradient elution is used. PCP can be determined directly in water at a lower limit of detection Of 0.2 micrograms per liter. For extracts of sediment, PCP can be determined to a lower limit of 1.0 micrograms per kilogram.
Publication type Report
Publication Subtype USGS Numbered Series
Title Determination of pentachlorophenol in water and aquifer sediments by high-performance liquid chromatography
Series title Open-File Report
Series number 82-124
DOI 10.3133/ofr82124
Edition -
Year Published 1981
Language ENGLISH
Publisher U.S. Dept. of the Interior, Geological Survey,
Description 15 p. ;28 cm.