A field calibration of the sediment-trapping characteristics of the Helley-Smith bed-load sampler

Professional Paper 1139
By:

Links

Abstract

For sediment particle sizes between 0.50 mm and 16 mm, the Helley-Smith bedload sampler has a near perfect sediment-trapping efficiency. For particles sizes smaller than 0.50 mm, the Helley-Smith sampler has a high bedload sediment-trapping efficiency because part of the sediement retained by the sampler has been transported in suspension and it cannot be quantified separately from the bedload. For particle sizes larger than about 16 mm, the Helley-Smith sampler has low sediment-trapping efficiency but this may be related to the paucity of coarse particles in transport in the calibration tests rather than reflecting an actual low trap efficiency for large-size particles. (USGS)
Publication type Report
Publication Subtype USGS Numbered Series
Title A field calibration of the sediment-trapping characteristics of the Helley-Smith bed-load sampler
Series title Professional Paper
Series number 1139
DOI 10.3133/pp1139
Edition -
Year Published 1980
Language ENGLISH
Publisher U.S. Govt. Print. Off.,
Description 44 p.
Google Analytic Metrics Metrics page
Additional publication details