Geology and preliminary hydrogeologic characterization of the cell-house site, Berlin, New Hampshire, 2003-04

Scientific Investigations Report 2004-5282
By: , and 

Links

Abstract

At the cell-house site, thin, generally less than 20-foot thick overburden, consisting of till and demolition materials, overlies fractured crystalline bedrock. Bedrock at the site consists of gneiss with thin discontinuous lenses of chlorite schist and discontinuous tabular pegmatite. Two distinct fracture domains, with principal trends to the west and northwest, and to the north, overlap near the site. The cell-house site shows principal trends common to both domains. Gneiss is the most abundant rock at the site. Steeply dipping fractures within the gneiss terminate on subhorizontal contacts with pegmatite and on moderately dipping contacts with chlorite schist. Steeply northwest-dipping en Echelon fracture zones, parallel joint zones, and silicified brittle faults show consistent strikes to the northeast. Gently east-dipping to subhorizontal fractures, sub-parallel to gneissosity, strike northeast. The impermeable cap, barrier wall, and bedrock surface topography affect ground-water flow in the overburden. There is relatively little ground-water flow in the overburden in the capped area and a poor hydraulic connection between the overburden and the underlying bedrock over most of the site. The overburden beneath the cap may receive inflow through or beneath the barrier wall, or by flow through vertical fractures in the underlying bedrock beneath the barrier wall. The bedrock aquifer near the river is well connected to the river and head difference in the bedrock across the site are large (greater than 13 ft). Horizontal hydraulic conductivities of 0.2 to 20 ft/d were estimated for the bedrock. Individual fractures or fracture zones likely have hydraulic conductivities greater than the bulk rock. Subhorizontal fractures occur at pegmatite contacts or along chlorite schist lenses and may serve as ground-water conduits to the steeply dipping fractures in gneiss. The effective hydraulic conductivity across the site is likely to be in the low range of the estimated values (0.2 ft/d). Ground water discharges to the river from the bedrock aquifer and is greatest during periods of large river stage fluctuations.
Publication type Report
Publication Subtype USGS Numbered Series
Title Geology and preliminary hydrogeologic characterization of the cell-house site, Berlin, New Hampshire, 2003-04
Series title Scientific Investigations Report
Series number 2004-5282
DOI 10.3133/sir20045282
Edition Online only
Year Published 2005
Language ENGLISH
Description 65 p.
Scale 5000000
Online Only (Y/N) Y
Google Analytic Metrics Metrics page
Additional publication details