Determination of uranium in natural waters

Water Supply Paper 1696-C
By: , and 

Links

Abstract

A method is described for the determination of very low concentrations of uranium in water. The method is based on the fluorescence of uranium in a pad prepared by fusion of the dried solids from the water sample with a flux of 10 percent NaF 45.5 percent Na2CO3 , and 45.5 percent K2CO3 . This flux permits use of a low fusion temperature and yields pads which are easily removed from the platinum fusion dishes for fluorescence measurements. Uranium concentrations of less than 1 microgram per liter can be determined on a sample of 10 milliliters, or less. The sensitivity and accuracy of the method are dependent primarily on the purity of reagents used, the stability and linearity of the fluorimeter, and the concentration of quenching elements in the water residue. A purification step is recommended when the fluorescence is quenched by more than 30 percent. Equations are given for the calculation of standard deviations of analyses by this method. Graphs of error functions and representative data are also included.
Publication type Report
Publication Subtype USGS Numbered Series
Title Determination of uranium in natural waters
Series title Water Supply Paper
Series number 1696
Chapter C
DOI 10.3133/wsp1696C
Edition -
Year Published 1965
Language ENGLISH
Publisher U.S. G.P.O.,
Description iii, 25 p. :ill. ;23 cm.
Google Analytic Metrics Metrics page
Additional publication details