Casing detector and self-potential logger

Groundwater
By:

Links

Abstract

A simple and rapid method of determining casing length and permeable zones in wells tapping bedrock can be useful to well drillers and hydrologists. A device consisting of a galvanometer, a reel of insulated wire, and a copper electrode locates the casing depth, changes of lithology, and permeable zones. The small-diameter electrode permits measurement through well-seal access ports avoiding the expensive and time-consuming procedure of removing the seal and drop pipes to measure casing depth with a magnet. The measured electromotive force changes rapidly when the electrode passes the end of casing. Thus, the depth of casing is easily determined from the length of wire payed out. Changes in electromotive force measured within the uncased part of a well frequently indicate permeable zones, thereby aiding in choice of the most efficient drop-pipe length, and also yielding useful information for hydrogeologic studies.

Publication type Article
Publication Subtype Journal Article
Title Casing detector and self-potential logger
Series title Groundwater
DOI 10.1111/j.1745-6584.1969.tb01668.x
Volume 7
Issue 6
Year Published 1969
Language English
Publisher National Ground Water Association
Description 4 p.
First page 24
Last page 27
Google Analytic Metrics Metrics page
Additional publication details