A method for adjusting values of Manning's roughness coefficient for flooded urban areas

Journal of Research of the U.S. Geological Survey
By:

Links

Abstract

A method is presented for adjusting values of Manning's roughness coefficient for flooded urban areas on the basis of the density of buildings on a flood plain and verified roughness coefficients for natural conditions. An urban roughness coefficient can be calculated to emulate the water-surface profiles to within 0.06 meter for depths of flow less than 0.6 meter and plus or minus 10 percent for depths between 0.6 and 2 meters.

Publication type Article
Publication Subtype Journal Article
Title A method for adjusting values of Manning's roughness coefficient for flooded urban areas
Series title Journal of Research of the U.S. Geological Survey
Volume 5
Issue 5
Year Published 1977
Language English
Publisher U.S. Geological Survey
Publisher location Reston, VA
Description 5 p.
First page 541
Last page 545
Online Only (Y/N) N
Additional Online Files (Y/N) N
Google Analytic Metrics Metrics page
Additional publication details